fix: detect mtime changes in _get_client to prevent stale HNSW index (#757)
When external tools write to the palace database (CLI mining, scripts), the MCP server's cached ChromaDB collection becomes stale — its HNSW index doesn't know about new vectors. Develop already invalidates on inode changes (catches rebuilds) but not on mtime changes (misses in-place writes). This PR: - Adds st_mtime tracking alongside st_ino in _get_client; invalidates the cached client on either change. - Adds the mempalace_reconnect MCP tool for explicit cache flush. Original author: @jphein (#663). Original approval: @Ari4ka. Skips test_missing_db_invalidates_cache on Windows (ChromaDB holds chroma.sqlite3 open).
This commit is contained in:
committed by
GitHub
parent
39e1651af3
commit
e200ce2c8a
+74
-3
@@ -15,6 +15,9 @@ Tools (read):
|
||||
Tools (write):
|
||||
mempalace_add_drawer — file verbatim content into a wing/room
|
||||
mempalace_delete_drawer — remove a drawer by ID
|
||||
|
||||
Tools (maintenance):
|
||||
mempalace_reconnect — force cache invalidation and reconnect after external writes
|
||||
"""
|
||||
|
||||
import argparse
|
||||
@@ -70,6 +73,7 @@ else:
|
||||
_client_cache = None
|
||||
_collection_cache = None
|
||||
_palace_db_inode = 0 # inode of chroma.sqlite3 at cache time
|
||||
_palace_db_mtime = 0.0 # mtime of chroma.sqlite3 at cache time
|
||||
|
||||
|
||||
# ==================== WRITE-AHEAD LOG ====================
|
||||
@@ -127,20 +131,50 @@ def _get_client():
|
||||
|
||||
Detects palace rebuilds (repair/nuke/purge) by checking the inode of
|
||||
chroma.sqlite3. A full rebuild replaces the file, changing the inode.
|
||||
Also detects external writes (scripts, CLI) via mtime changes — the
|
||||
inode check alone misses in-place modifications that invalidate the
|
||||
in-memory HNSW index.
|
||||
|
||||
Note: FAT/exFAT may return 0 for st_ino — the ``current_inode != 0``
|
||||
guard skips reconnect detection on those filesystems (safe fallback).
|
||||
"""
|
||||
global _client_cache, _collection_cache, _palace_db_inode, _metadata_cache, _metadata_cache_time
|
||||
global \
|
||||
_client_cache, \
|
||||
_collection_cache, \
|
||||
_palace_db_inode, \
|
||||
_palace_db_mtime, \
|
||||
_metadata_cache, \
|
||||
_metadata_cache_time
|
||||
db_path = os.path.join(_config.palace_path, "chroma.sqlite3")
|
||||
try:
|
||||
current_inode = os.stat(db_path).st_ino
|
||||
st = os.stat(db_path)
|
||||
current_inode = st.st_ino
|
||||
current_mtime = st.st_mtime
|
||||
except OSError:
|
||||
current_inode = 0
|
||||
current_mtime = 0.0
|
||||
|
||||
if _client_cache is None or current_inode != _palace_db_inode:
|
||||
# If the DB file disappeared (e.g. during rebuild) but we have a cached
|
||||
# collection, invalidate so we don't serve stale data. Without this,
|
||||
# both stored and current values are 0 on the first call after deletion,
|
||||
# making inode_changed and mtime_changed both False.
|
||||
if not os.path.isfile(db_path) and _collection_cache is not None:
|
||||
_client_cache = None
|
||||
_collection_cache = None
|
||||
_palace_db_inode = 0
|
||||
_palace_db_mtime = 0.0
|
||||
# Fall through to normal reconnect which will handle missing DB
|
||||
|
||||
inode_changed = current_inode != 0 and current_inode != _palace_db_inode
|
||||
mtime_changed = current_mtime != 0.0 and abs(current_mtime - _palace_db_mtime) > 0.01
|
||||
|
||||
if _client_cache is None or inode_changed or mtime_changed:
|
||||
_client_cache = chromadb.PersistentClient(path=_config.palace_path)
|
||||
_collection_cache = None
|
||||
_metadata_cache = None
|
||||
_metadata_cache_time = 0
|
||||
_palace_db_inode = current_inode
|
||||
_palace_db_mtime = current_mtime
|
||||
return _client_cache
|
||||
|
||||
|
||||
@@ -973,6 +1007,32 @@ def tool_memories_filed_away():
|
||||
}
|
||||
|
||||
|
||||
# ==================== SETTINGS TOOLS ====================
|
||||
|
||||
|
||||
def tool_reconnect():
|
||||
"""Force the MCP server to drop the cached ChromaDB collection and reconnect.
|
||||
|
||||
Use after external scripts or CLI commands modify the palace database
|
||||
directly, which can leave the in-memory HNSW index stale.
|
||||
"""
|
||||
global _collection_cache, _palace_db_inode, _palace_db_mtime
|
||||
_collection_cache = None
|
||||
_palace_db_inode = 0
|
||||
_palace_db_mtime = 0.0
|
||||
try:
|
||||
col = _get_collection()
|
||||
if col is None:
|
||||
return {
|
||||
"success": False,
|
||||
"message": "No palace found after reconnect",
|
||||
"drawers": 0,
|
||||
}
|
||||
return {"success": True, "message": "Reconnected to palace", "drawers": col.count()}
|
||||
except Exception as e:
|
||||
return {"success": False, "error": str(e)}
|
||||
|
||||
|
||||
# ==================== MCP PROTOCOL ====================
|
||||
|
||||
TOOLS = {
|
||||
@@ -1321,6 +1381,17 @@ TOOLS = {
|
||||
"input_schema": {"type": "object", "properties": {}},
|
||||
"handler": tool_memories_filed_away,
|
||||
},
|
||||
"mempalace_reconnect": {
|
||||
"description": (
|
||||
"Force reconnect to the palace database. Use after external scripts or CLI commands"
|
||||
" modified the palace directly, which can leave the in-memory HNSW index stale."
|
||||
),
|
||||
"input_schema": {
|
||||
"type": "object",
|
||||
"properties": {},
|
||||
},
|
||||
"handler": tool_reconnect,
|
||||
},
|
||||
}
|
||||
|
||||
|
||||
|
||||
Reference in New Issue